此系列电流传感器可以用于多种高要求应用。例如,我们的 60A 版本允许以更高水平的准确度、性能和可靠性控制系统。此传感器按照我们的 0 维护原则设计:无需单独校准传感器,性能极为可靠。
另一方面,1200A 版本具有现有高精度电流传感器的最高额定电流。可无缝安装在用于 MRI 应用的现有或新梯度放大器系统中。独特技术提高了电流测量的准确度,实现的图像质量和可靠性超出行业标准。XPCS-1200 是浦卓科技在高精度电子元件方面 20 年行业标杆的体现。
联系我们Typical | Unit | |
Current range | 440 | Arms |
±1200 | Apk | |
Linearity | 3.3 | ppm |
Flatness up to 1 kHz | 0.01 | dB |
Bandwidth (45 deg | 800 | kHz |
Noise floor <10kHz | 500 | nA/√Hz |
Noise 1/f corner | 20 | Hz |
Isolation | 5 | KVrms |
IEC-60601 | 2 x MOOP (Means of Operator Protection) | |||
External CLK input Synchronization |
- Shielded SUB-D 9pin connector for secondary circuits |
- Operation Status: if sensor is in normal operation state and no overcurrent has occurred, pin 2 is pulled down. |
- Sync Status: if sensor is synchronized with the provided external signal, pin 8 is pulled down. |
- Power Supplies: +/-15V (+/-5% tolerance) |
- Current Output: ISEC is positive when IPRIM flows in the direction shown by the arrow |
- SMA connector for external synchronization signal (TTL) |
- Green LED that is ON during normal operation and OFF if any error occurs |
This product range is not available separately but is shown here to demonstrate what can be achieved. However, we will gladly discuss any projects where there is a need for this level of accuracy.
No MOQ applicable