Product features
NG Tool Suite enables easy access across NG Series product portfolio from initial integration to in-field remote diagnostics via Ethernet connection HMI
Seamless integration into new and current systems by using our flexible control interface. Existing interface can be easily installed in the whole NG series portfolio.
Customer specific branding is possible, to align within customer product portfolio.
Min | Typical | Max | Unit | |
Mains | 380 | 480 | VAC +/- 10% | |
50 | 60 | Hz | ||
Mains switch included | ||||
Power Factor Correction (PFC) | Unity power factor & low harmonics | |||
Programmable bus voltage | 1200 | 2100 | Vdc | |
Mains input power | 90 | kVA | ||
Available power to end stage | 65 | kW per axis | ||
82 | kW for three axis |
Min | Typical | Max | Unit | |
Output voltage (at Ipeak) | +/-1900 | V | ||
Output current | 1200 | Apk | ||
400 | Arms Continuous or DC | |||
Load range | 0.22 | 4.7 | mH | |
50 | 350 | mΩ | ||
Patented end stage included | ||||
Integrated output filter (fcorner<switching frequency) |
Min | Typical | Max | Unit | |
Settling time | error<1% after 100µs | |||
error<0.4% after 150µs | ||||
error<0.1% after 250µs | ||||
Drift offset typical | 5mA/°C | |||
Drift gain typical | 10ppm/°C | |||
Propagation delay | <70µs | |||
Linearity | <100ppm | |||
Bandwith | >10 | kHz | ||
Total harmonic distortion | <0.4% at 360Arms/200Hz | |||
<0.8% at 360Arms/1kHz | ||||
Initial offset: neglectable (auto-zero ) | ||||
High precision current sensors included |