Product features
Customer specific branding is possible, to align within customer product portfolio.
Seamless integration into new and current systems by using our flexible control interface. Existing interface can be easily installed in the whole NG series portfolio.
NG Tool Suite enables easy access across NG Series product portfolio from initial integration to in-field remote diagnostics via Ethernet connection HMI
Min | Typical | Max | Unit | |
Mains (single phase) | 100 | 240 | VAC +/- 10% | |
50 | 60 | Hz | ||
Prated | 750 | W | ||
Tolerant to mains dips and swells | ||||
C20 connector on front |
Min | Typical | Max | Unit | |
Output voltage | +/-30 | V | ||
Induced voltage handling capability | 50 | V | ||
Induced current (peak/RMS) | 10/5 | A | ||
Output Current (low impedance output) | +/-7 | Adc | ||
Maximum continuous output power (total combined) | 650 | W | ||
Load range | 0.5 | 20 | mH | |
1 | 6 | Ω |
Min | Typical | Max | Unit | |
Settling time | 100 | ms | ||
Initial gain error | <1 | % | ||
Offset error | 5 | mA | ||
Drift (self-heating) | <500 | ppm | ||
Drift (ambient) | <100 | ppm/K | ||
Linearity error | <0.1 | % |